WT-62U Digital Window Thermometer
Features:
Clear functional design
Easy to read outdoor temperature from indoors
Maximum and minimum values with auto reset
Easy to mount
Weather resistant
Specifications:
Measuring range: -22 ºF to +122 ºF
Resolution: 0.2 ºF
Temperature Updating Interval: Every 10 Seconds
Battery: 1 AAA
Inserting the Battery:
1. The battery cover is located on the back of the
thermometer.
2. Using your fingers slide the battery cover off of the battery compartment.
3. Observing the correct polarity insert one AAA battery into the battery compartment.
4. Replace the battery cover.
Setting the Time:
1. Press the MODE button to enter the setting mode.
2. The hours digits will flash in the center of the display.
3. Press and release the + button to advance the hour.
NOTE: When in the hours between midnight and noon, A.M. will be displayed on the left of the display. When in the
hours between noon and midnight P.M. will be displayed on the left side of the display.
4. Press and release the MODE button to confirm the hour and advance to the minute setting.
5. The minutes digits will flash at the bottom of the display.
6. Press and release the + button to advance the minute.
7. Holding down the + button will advance the minutes faster.
8. Press and release the MODE button to confirm the minutes and exit the time setting mode.
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1

1WT-62U Digital Window Thermometer Features: • Clear functional design • Easy to read outdoor temperature from indoors

Page 2

7PROGRAM MODE Programming Note: If 30 seconds are allowed to pass or either the IN or the OUT button is pressed during programming modes, the unit w

Page 3

8II. FUNCTION KEYS The function keys are operated by pressing the key corresponding to the operation that you want to perform. II. 12 OR 24 HOUR

Page 4

94. Select your appropriate time zone using the “CH” button. During selection of the Time Zone, the 3 letter abbreviations for the time zones found

Page 5 - Table Of Contents

10 6. Press and release the “SET” button to confirm and advance to the Time setting mode. V. TIME There are two methods by which the time can be

Page 6 - Figure 2

115. Press and release the “SET” button to confirm the hour setting and to advance to the minute setting mode. 6. The minute digits should be flas

Page 7

125. The numeric-month will be flashing in the DATE LCD. Press and release the “CH” button to select to the current month. 6. Press and release th

Page 8

13VIII. SETTING THE LCD CONTRAST 1. Press and hold the “SET” button for 3 seconds or until “12h” or “24h” flashes in the DATE LCD. 2. Press and r

Page 9 - Battery

14FEATURES OF THE WS-9013U I. INDOOR TEMPERATURE The current indoor is displayed in the INDOOR LCD and is updated every 10 seco

Page 10

15 III. MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-9013U keeps a record of the MINIMUM and MAXIMUM temperature and the time and date of their o

Page 11

16 C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS 1. All the indoor records (minimum and maximum) will be reset after the “IN” button is pressed and

Page 12

2NOTE: The thermometer will automatically time out and return to the normal display mode after approximately 30 seconds. Installation: 1. Select

Page 13

173. Place all remote temperature sensor units in a numeric sequential order. 4. In sequential order, install batteries (follow the same battery in

Page 14

18 MOUNTING Note: Before permanently mounting ensure that the indoor weather station is able to receive WWVB signals from the desired location. A

Page 15

19ensure a secure hold. The mounting surface should be smooth and flat. 2) Remove the protective strip from one side of the tape. Adhere the tape

Page 16

20 TROUBLESHOOTING Problem: No reception of WWVB time signal. Solution: 1) Wait overnight for signal. 2) Be sure indoor weather station is at least

Page 17

21• Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology for repairs. SPECIFICATIONS Tempe

Page 18

22 WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and w

Page 19

23ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS

Page 20

3WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and wor

Page 21

WS-9013U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual

Page 22

2 Topic Page Inventory of Contents/Additional Equipment 3 About WWVB 4 Quick Set-Up Guide 5 Detailed Set-Up

Page 23

3 INVENTORY OF CONTENTS 1. The weather station (Figure 1). 2. One TX6U remote temperature sensor with mounting bracket (Figure 2). 3. Th

Page 24

4ABOUT WWVB (Radio Controlled Time) The NIST (National Institute of Standards and Technology—Time and Frequency Division) WWVB radio station is lo

Page 25

5QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor weather station and remote temp

Page 26

6DETAILED SET-UP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket. The bracket snaps on and off