PROFESSIONAL WEATHER CENTER
WS-1613-IT
Operation Manual
IMPORTANT:
When a battery change is required on any of the units of this set, ALL units
have to be reset and user must go through initial set-up steps again.
1
Table of Contents
Topic Page
Features 3
Setting up 6
Function keys 12
LCD Screen 14
Manual Setting 16
Time alarm setting 24
Weather alarm operations 25
Hysteresis 31
Weather forecast and weather tendency 32
Wind direction and wind speed measurement 36
Rainfall measurement 37
Viewing history data 37
Viewing the min/ max weather data 39
Switch On/ Off buzzer 46
Outdoor transmission 915 MHz reception 48
Positioning 49
Care and Maintenance 53
Specification 54
Warranty Info 56
2
PROFESSIONAL WEATHER CENTER
Instruction Manual
Congratulations on purchasing this state-of-the-art Professional Weather Center as an
example of excellent design and innovative technology. Featuring time, date,
calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature
and outdoor humidity, air pressure and various alarm settings for different weather
conditions, this Weather Center will provide you with extensive weather information
and forecast.
INSTANT TRANSMISSION is the
state-of-the-art new wireless
transmission technology, exclusively
designed and developed by LA
CROSSE TECHNOLOGY. INSTANT
TRANSMISSION
offers you an
immediate update (every 4 seconds!)
of all your outdoor data measured
from the transmitters: follow your
climatic variations in real-time!
This
p
roduct offers:
3
FEATURES:
Weather Center
Time display (manual setting)
12/24 hour time display
Calendar display (weekday, date, month, year)
Time alarm function
Weather forecasting function with 3 weather icons and weather tendency
indicator
Outdoor temperature display in ºF/°C
Outdoor Humidity display as RH%
MIN/MAX value of outdoor temperature and humidity display with time & date of
recording
Function keys
LCD
Foldout stand
Battery compartment
cover
Hanging hole
4
Low/High outdoor temperature and humidity alarm
Relative air pressure displayed in inHg or hPa
Air pressure tendency indicator for the past 12 hours (bargraph format)
LCD contrast selectable
Low battery indicator
Wind direction displayed in 16 steps
Wind speed displayed in mph, km/h, or m/s, and Beaufort scale
Wind chill displayed in °F of °C
Max wind speed displayed with time & date of recording
High alarm function for wind speed
Manual reset of outdoor temperature/ humidity, pressure and wind chill data
Total rainfall displayed in mm or inch
Storm warning alarm
Buzzer on/off selectable
Storage of 200 sets of history weather data recorded in 3-hour intervals
Wireless transmission at 915 MHz
Transmission range up to 330 feet (100 meters)
Thermo-hygro Sensor
Remote transmission of the outdoor temperature and humidity
to the Weather Center at 915 MHz
Weather-resistant casing
Wall mounting case (to be mounted in a sheltered place. Avoid
direct rain and sunshine)
5
Wind Sensor
Connected to the thermo-hygro sensor by cable
Can be installed onto a mast or a horizontal panel
Rain Sensor
Connected to the thermo-hygro sensor by cable
To be mounted onto a horizontal panel
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - WS-1613-IT

PROFESSIONAL WEATHER CENTER WS-1613-IT Operation Manual IMPORTANT: When a battery change is required on any of the units of this s

Page 2

54 To wall mount: 1. Fix a screw (not supplied) into the desired wall, leaving the head extended out the by about 5mm. 2. Hang the Bonus Receiver

Page 3 - LCD SCREEN

6 Cable connection between the wind sensor and the thermo-hygro sensor Cable connection between the rain sensor and the thermo-hygro sensor Wireless

Page 4 - TIME ALARM SETTING

12 The Bonus Receiver use 2 x AA, IEC LR6, 1.5V batteries. When the batteries need to be replaced, the low battery symbol will appear on the LCD. To

Page 5 - HYSTERESIS

18 CALENDAR SETTING: The date default of the Weather Center is 1. 1. of year 2005. The date can be set manually by proceeding as follows. 1.

Page 6 - VIEWING THE HISTORY DATA

24 2. Press and hold the SET key for about 2 seconds. The hour digit of the alarm time will start flashing. Press the + or MIN/MAX key to set the h

Page 7

30 drops to +76.8°F (24.9°C) or below and thereafter again increases to beyond +77°F (25°C), the data will be blinking, but no alarm will be activat

Page 8 - POSITIONING

36 To view the weather history: 1. Press the HISTORY key. The latest weather record will be shown with the date and time of recording. The "HIS

Page 9 - MANUAL SETTINGS:

42 2. Press and hold the SET key for about 2 seconds, then the "RESET" icon will appear at the bottom part of the LCD. 3. Press the + key

Page 10 - WARRANTY

48 mounted using the screw or cable tie provided onto a solid wall/ panel mast or mast to allow the wind to travel around the sensor unhindered from