C86234 Wireless Professional Weather Center Operations Manual Revision: 8
MIN/MAX • Press to display minimum and maximum records of various weather data • Stop the weather alarm when ringing LCD SCREEN When the sign
LCD CONTRAST SET The LCD contrast can be set within 8 levels; from "Lcd 1" to "Lcd 8" (default setting is "Lcd 5"): 1
°F/°C TEMPERATURE UNIT: The temperature can be displayed in °F or °C. (Default °F) 1. The temperature unit will flash. 2. Press the ▲/DATE button
RELATIVE PRESSURE REFERENCE VALUE: Note: For an exact measurement, it is necessary to adjust the barometer to the local relative air pressure (relate
STORM ALARM ON/ OFF SET: The storm warning display (flashing downward weather tendency arrow) can be accompanied by a ring of the alarm. Switch the
4. After waiting for 10 minutes, insert the batteries into the thermo-hygro sensor, and rain sensor making sure to align the "+" symbol on
DEFAULT WEATHER ALARM VALUES: Pressure Low 28.35 inHg Wind gust High 62.0mph High 30.71 inHg Wind Direction North Temperature (In or Out) Low 32°F
7. Press and hold the SET button for about 2 seconds. The temperature digit will flash. 8. Press the ▲/DATE button or ▼/RAIN button to set the low
10. Press the SET button to switch the alarm on or off. The ((())) icon indicates the alarm is switched on. 11. Press the ALARM button to move to the
5. To remove an alarm setting for a wind direction, press the SET button again to remove the selected wind direction alarm. The arrow icon inside the
INTRODUCTION ongratulations on purchasing this state-of-the-art weather station. Featuring time, date, weather forecast, wind gust and wind speed, in
DISPLAY MODES MODE 1 Press and release the SET button to toggle between Mode 1 and Mode 2 display: • Pressure history graph displays 24 hour histor
check in the setting mode –see WEATHER TENDENCY SENSITIVITY in the manual settings above. The displayed icon forecasts the weather in terms of gettin
The vertical bars are plotted at each of the seven steps and give the trend over the recorded period. The 0 hour vertical bar will always display at t
RAINFALL MEASUREMENT The 1hour, 24-hour, week, month or total rainfall measurement is displayed on the LCD, in the unit of inch or mm. For all meas
RESET TOTAL RAINFALL AMOUNT The total rainfall measurement is displayed in the unit of mm or inch. It shows the total rainfall accumulated since las
MOUNTING AND PLACEMENT OF SENSORS AND DISPLAY IMPORTANT: Ensure that all of the sensor data can be received at the intended mounting locations befo
WIND SENSOR The wind sensor must be installed with the front of the sensor (the solar panel) facing true South, or the reported wind direction will n
THERMO-HYGRO SENSOR The thermo-hygro sensor is "weather resistant", but not "water proof". • To ensure an extended life for the
OUTDOOR HUMIDITY 3% to 99% (“- -” displayed if < 1%, "99" displayed if ≥ 99%) WIND SPEED/ GUST 0 to 111.8 mph with resolution of 0.22
RAIN SENSOR 2 x AA size batteries (IEC LR6, 1.5V) Approximately 24 months (Alkaline batteries recommended) WIND SENSOR 100% solar-powered (built-in
Date set: ... 11 °F/°C
• Never touch the exposed electronic circuit of the device as there is a danger of electric shock should it become exposed. • Do not expose the disp
WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and wor
For warranty work, technical support, or information contact: La Crosse Technology, Ltd 2817 Losey Blvd. S. La Crosse, WI 54601 Contact Support: 1
Relative Humidity ... 24 Wind Chill-E
INVENTORY OF CONTENTS Carefully open the package and check that the following contents are complete: Wind Sensor Rain Sensor Thermo-Hygro Sensor Wire
FEATURES WIRELESS DISPLAY C86234 Weather station works with or without a computer • 12/24 hr. time & calendar with date, month & year • Ma
WIRELESS SOLAR POWERED WIND SENSOR (TX63U-IT) • 100% solar-powered (built-in power cell, no batteries necessary) • High-efficiency solar panels mai
Press Reset Button on Bottom of Wind Sensor (Solar Panel Must Face Light) STEP 1: • Complete initial setup on a table with all components within 10 f
FUNCTION BUTTONS SET • Hold for 3 seconds to enter the SET mode, where the following can be changed: LCD contrast, Manual time setting, 12/24